SPECIFICATIONS
Common Specifications
1. Rating : 50mA 12V DC (Resistive Load) |
||
2. Electrical Performance |
||
Item |
Test Condition |
Performance |
Contact Resistance |
1A 5V DC |
As per Individual Specifications |
Insulation Resistance |
100V DC for 1 minute |
100MΩ |
Withstanding Voltage |
250V AC for 1 minute |
Shall be free from Dielectric Breakage |
3. Mechanical Performance |
||
Item |
Test Condition |
Performance |
Operating Force |
|
As per Individual Specifications |
Stop Strength |
3kgf for c seconds |
No Deformation and Mechanical Problem Found |
Bounce |
The Key Shall be Struck Lightly at it's Center at a Uniform Cycling Rate of 3Operations Per Second |
As per Individual Specifications |
4. Endurance |
||
Item |
Test Condition |
Performance |
Life Test |
2-3 Cycles/Second with 5V DC 5mA Resistive Load Cycles of Operation:As per Individual Specifications. |
‧Contact Resitance : As per Individual Specifications |
Dry Heat Proof |
80℃ ± 2℃ for 96 Hours After Test. |
Equality to Initial Specifications |
Moisture Resistance |
60℃ ± 2℃ 90~95%RH for Hours After Test. Kept in Normal Condition for 30 Minutes. |
Equality to Initial Specifications |
Cold Proof |
-30℃ for 96 Hours After Test. |
Equality to Initial Specifications |
5. Solder Heat Resistance & Auto Soldering:255℃ for 5 Seconds |
||
6. Explanation of Timing |
||
Item |
Explanation |
Figure |
Operation Force |
It refers to the maximum load at the time of switching over of the contacts.(Point A in the figure) |
|
Return Force |
It refers to the returning force of the stem after its full travel when pushed out.(Point B in the Figure) |
|
Click |
It refers to the feeling indicated on the inversion portion in the operating force us. Travel diagram shown en the figure. |
|
Travel |
It refers to the distance of travel of the operating part before the contacts is changed over. Generally, it is about 0.3mm in mechanical contact. |
|
Bounce |
This refers to the state of repeating the contact opening or closing momentarily at the time of the changeover of the swich to ON or OFF longer duration of this state may cause malfunction of the signal |
|
|
|
|
Common Specifications
1. Rating : AS per Individual Specifications |
||
2. Electrical Performance |
||
Item |
Test Condition |
Performance |
Contact Resistance |
1A 5V DC |
As per Individual Specifications |
Insulation Resistance |
500V DC for 1 minute |
100MΩ Min |
Withstanding Voltage |
500V AC for 1 minute |
Shall be free from |
3. Mechanical Performance |
||
Item |
Test Condition |
Performance |
Operating Force |
|
As per Individual Specifications |
Terminal Strength |
500gf for 1minute |
No Terminal Rejection |
4. Endurance |
||
Item |
Test Condition |
Performance |
Life Test |
10,000 Cycle Operations |
‧Contact Resistance : PS Series : 100MΩ |
Cold Proof |
-20±3℃ for 96 Hours |
‧Contact Resistance : 200MΩ |
Dry Heat Proof |
80±2℃ for 96 hours |
|
Common Specifications
1. Rating : AS per Individual Specifications |
||
2. Electrical Performance |
||
Item |
Test Condition |
Performance |
Contact Resistance |
1A 5V DC |
As per Individual Specifications |
Insulation Resistance |
500V DC for 1 minute |
100MΩ Min |
Withstanding Voltage |
500V AC for 1 minute |
Shall be free from |
3. Mechanical Performance |
||
Item |
Test Condition |
Performance |
Operating Force |
|
As per Individual Specifications |
Terminal Strength |
500gf for 1minute |
No Terminal Rejection |
4. Endurance |
||
Item |
Test Condition |
Performance |
Life Test |
10,000 Cycle Operations |
‧Contact Resistance : PS Series : 100 |
Cold Proof |
-20±3℃ for 96 Hours |
‧Contact Resistance : 200MΩ Max |
Dry Heat Proof |
80±2℃ for 96 hours |
|
Common Specifications
1. Rating : AS per Individual Specifications |
||
2. Electrical Performance |
||
Item |
Test Condition |
Performance |
Contact Resistance |
1mA 5V DC |
20MΩ Max |
Insulation Resistance |
500V DC for 1 minute |
100MΩ |
Withstanding Voltage |
500V AC for 1 minute |
Shall be free from Dielectric Breakage |
3. Mechanical Performance |
||
Item |
Test Condition |
Performance |
Operating Force |
|
As per Individual Specifications |
Stop Strength |
500gf for 1minute |
No Terminal Rejectionand Insulator Breakage |
Lever strength |
2Kgf for 15 seconds |
No Deformation and Mechanical Problem Found |
4. Endurance |
||
Item |
Test Condition |
Performance |
Life Test |
10,000 Cycle Operations |
‧Contact Resistance : 100MΩ |
Cold Test |
-20±3℃ for 48±5 Hours |
Equality to Initial Specifications |
Dry Heat Proof |
80±2℃ for 48±55 hours |
Equality to Initial Specifications |
5. Solder Heat Resistance : Auto Soldering : 260° ± 5℃/3Seconds
Manual Soldering : 350° ±5℃/3Seconds
6. Explanation of Changeover Timing
Shorting |
Non-shorting |
|||||||||||||||
Switching action is accomplished after electrical connections have been made once across terminals during circuit selection.(Terminals① ,② and ③ |
Electrical connections are turned off once across terminals during circuit selection. |
|||||||||||||||
|
① ② ③ |
① ② ③ |
① ② ③ |
① ② ③ |
① ② ③ |
|||||||||||
↓ ↓ ↓ |
↓ ↓ ↓ |
↓ ↓ ↓ |
↓ ↓ ↓ |
↓ ↓ ↓ |
↓ ↓ ↓ |
|||||||||||
|
||||||||||||||||
Stationary position |
During switching |
After switching |
Stationary position |
During switching |
After switching |
Common Specifications
1. Rating : 200mA 48V DC (Resistive Load) |
||
2. Electrical Performance |
||
Item |
Test Condition |
Performance |
Contact Resistance |
1A 5V DC |
50MΩ Max |
Insulation Resistance |
500V DC for 1 minute |
100MΩ Min |
Withstanding Voltage |
500V AC for 1 minute |
Not Breaking Insulation |
3. Mechanical Performance |
||
Item |
Test Condition |
Performance |
Operating Force |
|
As per Individual Specifications |
Terminal Strength |
300gf for 1minute |
No Terminal Rejection and Insulator Material Breakage |
Lever strength |
1Kg for Force for 15seconds |
There shall not be any Troubles as Deviation and Bending |
4. Mechanical Performance |
||
Item |
Test Condition |
Performance |
Life Test |
300,000 Cycle Without Load |
‧Contact Resistance : 1Ω Max |
Cold Test |
20±2℃ for 96 Hours |
‧Contact Resistance : 200mΩ Max |
Dry Heat Proof |
85±2℃ for 96 hours |
|
Moisture Resistance |
40±2℃ 90~95 RH for 96 hours |
5. Solder Heat Resistance : Auto Soldering : 260℃± 5℃/3 Seconds
Manual Soldering : 350℃±5℃/3 Seconds
Common Specifications
1. Construction |
||
NO |
Item |
Performance |
1-1 |
Dimension |
Shape and dimensions subject to attached chart requlation |
1-2 |
Appearance |
Every part should be finished not to exist rust flaw crack and bad plating |
2. Electrical Performance |
|||
NO |
Item |
Test Condition |
Performance |
3-1 |
Contact resistance |
DC 5V, 1A by voltage droop method |
30mΩ max. |
3-2 |
Insulation resistance |
DC 500V for 1 minute |
100mΩ min |
3-3 |
Withstand voltage |
AC 500V (50Hz or 60Hz)fir 1 minute |
No breakdown |
3. Mechanical Performance |
|||
NO |
Item |
Test Condition |
Performance |
4-1 |
Insulation force |
|
As per Individual Specifications |
4-2 |
Extraction force |
|
As per Individual Specifications |
4-3 |
Terminal strength |
500gf for 1 minute |
No Terminal Rejection and Insulator Breakage |
4-4 |
Lever strength |
1kgf for 15 seconds |
no mechanical and electrical problem |
4. Endurance |
|||
NO |
Item |
Test Condition |
Performance |
5-1 |
Operating life |
5,000 cycles (15~20 cycles/min) |
Contact Resistance : 50mΩ Max |
|
|
unloading |
Insulation resitance : 100mΩ min. |
|
|
|
Withstand voltage : AC 500V for 1 minute, no breakdown |
|
|
|
Insertion or extraction force: |
|
|
|
Within+10%~-30% of initial force |
5. Soldering |
||
NO |
Item |
Performance |
7-1 |
Automatic soldering |
260℃±5℃ 3sec. max |
7-2 |
Manual soldering |
350℃±5℃ 3sec. max |
Common Specifications
1. Construction |
||
NO |
Item |
Performance |
1-1 |
Dimension |
Shape and dimensions subject to attached chart requlation |
1-2 |
Appearance |
Every part should be finished not to exist rust flaw crack and bad plating |
2. Rating Performance |
|||
3. Electrical Performance |
|||
NO |
Item |
Test Condition |
Performance |
3-1 |
Contact resistance |
DC 5V, 1A by voltage droop method |
30mΩ max. |
3-2 |
Insulation resistance |
DC 500V for 1 minute |
100mΩ min |
3-3 |
Withstand voltage |
AC 500V (50Hz or 60Hz)fir 1 minute |
No breakdown |
4. Mechanical Performance |
|||
NO |
Item |
Test Condition |
Performance |
4-1 |
Insulation force |
|
As per Individual Specifications |
4-2 |
Extraction force |
|
As per Individual Specifications |
4-3 |
Terminal strength |
500gf for 1 minute |
No Terminal Rejection and Insulator Breakage |
4-4 |
Lever strength |
1 kgf for 15 seconds |
no mechanical and electrical problem |
5. Endurance |
|||
NO |
Item |
Test Condition |
Performance |
5-1 |
Operating life |
5,000 cycles (15~20 cycles/min) |
Contact Resistance : 50mΩ Max |
|
|
unloading |
Insulation resitance : 100mΩ min. |
|
|
|
Withstand voltage : AC 500V for 1 minute, no breakdown |
|
|
|
Insertion or extraction force: |
|
|
|
Within+10%~-30% of initial force |
6. Soldering |
||
NO |
Item |
Performance |
6-1 |
Being Kept in the condition at -20℃±3℃ for 48±5hours, then in normal condition for 1hour, to be measured within 1 hour Waterdrops shall be removed |
Equality to specification of No. 5-1 |
6-2 |
Being kept in the condition at80℃±2℃ for 48±5hours, then in normal condition for 1hour, to be measured within 1 hour |
Equality to specification of No. 5-1 |
7. Soldering |
||
NO |
Item |
Performance |
7-1 |
Automatic soldering |
260℃±5℃ 3sec. max |
7-2 |
Manual soldering |
350℃±5℃ 3sec. max |
Common Specifications