SPECIFICATIONS

 

       Common Specifications

1. Rating : 50mA 12V DC (Resistive Load)

2. Electrical Performance

Item

Test Condition

Performance

Contact Resistance

1A 5V DC

As per Individual Specifications

Insulation Resistance

100V DC for 1 minute

100Min

Withstanding Voltage

250V AC for 1 minute

Shall be free from Dielectric Breakage

 

3. Mechanical Performance

Item

Test Condition

Performance

Operating Force

 

As per Individual Specifications

Stop Strength

3kgf for c seconds

No Deformation and Mechanical Problem Found

Bounce

The Key Shall be Struck Lightly at it's Center at a Uniform Cycling Rate of 3Operations Per Second

As per Individual Specifications

 

4. Endurance

Item

Test Condition

Performance

Life Test

2-3 Cycles/Second with 5V DC 5mA Resistive Load Cycles of Operation:As per Individual Specifications.

‧Contact Resitance : As per Individual Specifications
‧Operating Force : ±30%Initial Value
‧Insulation Resistance : 10
 Min

Dry Heat Proof

80℃ ± 2℃ for 96 Hours After Test.
Kept in Normal Condition for 30 Min.

Equality to Initial Specifications

Moisture Resistance

60℃ ± 2℃ 90~95%RH for Hours After Test. Kept in Normal Condition for 30 Minutes.

Equality to Initial Specifications

Cold Proof

-30℃ for 96 Hours After Test.
Kept in Normal Condition for 30 Minutes.

Equality to Initial Specifications

 

5. Solder Heat Resistance & Auto Soldering:255℃ for 5 Seconds

6. Explanation of Timing

Item

Explanation

Figure

Operation Force

It refers to the maximum load at the time of switching over of the contacts.(Point A in the figure)

 

Return Force

It refers to the returning force of the stem after its full travel when pushed out.(Point B in the Figure)

Click
(tactile Feedback)

It refers to the feeling indicated on the inversion portion in the operating force us. Travel diagram shown en the figure.
The greater this inversion part is, the clearer it is to the operator that the switch is moved.

Travel

It refers to the distance of travel of the operating part before the contacts is changed over. Generally, it is about 0.3mm in mechanical contact.

Bounce

This refers to the state of repeating the contact opening or closing momentarily at the time of the changeover of the swich to ON or OFF longer duration of this state may cause malfunction of the signal

 

 

 

 

       Common Specifications

1. Rating : AS per Individual Specifications

2. Electrical Performance

Item

Test Condition

Performance

Contact Resistance

1A 5V DC

As per Individual Specifications

Insulation Resistance

500V DC for 1 minute

100MΩ Min

Withstanding Voltage

500V AC for 1 minute

Shall be free from
Dielectric Breakage

 

3. Mechanical Performance

Item

Test Condition

Performance

Operating Force

 

As per Individual Specifications

Terminal Strength

500gf for 1minute

No Terminal Rejection
and Insulator Breakage

 

4. Endurance

Item

Test Condition

Performance

Life Test

10,000 Cycle Operations
(15~20Cycles/Minute) Without Load

‧Contact Resistance : PS Series : 100 Max
‧Operating Force : +10,-30%Initial Value
‧insulation Resistance :10
Min
‧Withstand Voltage : 500V AC for 1minute

Cold Proof

-20±3℃ for 96 Hours
After Test, Kept in Normal Condition for 1Hours, to be Measured within 1Hour.

‧Contact Resistance : 200Max
‧Operatif Force : +10, -30%Initial Value
‧Insulation Resistance : 10
MΩ Min.
‧Withstanding Voltage : 500V AC for 1    Minute

Dry Heat Proof

80±2℃ for 96 hours
After Test, kept in Normal Condition for 1Hour, to be Measured within 1Hour.

 

5. Explanation of Changeover Timing

Shorting

Non-shorting

Switching action is accomplished after electrical connections have been made once across terminals during circuit selection.(Terminals① ,② and ③electrically connected once)

Electrical connections are turned off once across terminals during circuit selection.
(Terminals① ,② and ③ are electrically turned off once)

  ① ② ③  

① ② ③

① ② ③

① ② ③

    ① ② ③ 

① ② ③

↓   ↓   ↓ 

↓   ↓   ↓ 

↓   ↓   ↓

↓   ↓   ↓ 

↓   ↓   ↓ 

↓   ↓   ↓

 

        

 

   

 

 

 

    

 

 

 

Stationary position 

During switching 

After switching

Stationary position 

During switching 

After switching

 

       Common Specifications

1. Rating : AS per Individual Specifications

2. Electrical Performance

Item

Test Condition

Performance

Contact Resistance

1A 5V DC

As per Individual Specifications

Insulation Resistance

500V DC for 1 minute

100MΩ Min

Withstanding Voltage

500V AC for 1 minute

Shall be free from
Dielectric Breakage

 

3. Mechanical Performance

Item

Test Condition

Performance

Operating Force

 

As per Individual Specifications

Terminal Strength

500gf for 1minute

No Terminal Rejection
and Insulator Breakage

 

4. Endurance

Item

Test Condition

Performance

Life Test

10,000 Cycle Operations
(15~20Cycles/Minute) Without Load

‧Contact Resistance : PS Series : 100 Max
‧Operating Force : +10,-30%Initial Value
‧insulation Resistance :10M
Ω Min
‧Withstand Voltage : 250V AC for 1minute

Cold Proof

-20±3℃ for 96 Hours
After Test, Kept in Normal Condition for 1Hours, to be Measured within 1Hour.

‧Contact Resistance : 200MΩ Max
‧Operatif Force : +10, -30%Initial Value
‧Insulation Resistance : 10M
Ω Min.
‧Withstanding Voltage : 500V AC for 1    Minute

Dry Heat Proof

80±2℃ for 96 hours
After Test, kept in Normal Condition for 1Hour, to be Measured within 1Hour.

 

5. Explanation of Changeover Timing

Shorting

Non-shorting

Switching action is accomplished after electrical connections have been made once across terminals during circuit selection.(Terminals① ,② and ③electrically connected once)

Electrical connections are turned off once across terminals during circuit selection.
(Terminals① ,② and ③ are electrically turned off once)

  ① ② ③  

① ② ③

① ② ③

① ② ③

    ① ② ③ 

① ② ③

↓   ↓   ↓ 

↓   ↓   ↓ 

↓   ↓   ↓

↓   ↓   ↓ 

↓   ↓   ↓ 

↓   ↓   ↓

 

        

 

   

 

 

 

    

 

 

 

Stationary position 

During switching 

After switching

Stationary position 

During switching 

After switching

 

       Common Specifications

1. Rating : AS per Individual Specifications

2. Electrical Performance

Item

Test Condition

Performance

Contact Resistance

1mA 5V DC

20 Max

Insulation Resistance

500V DC for 1 minute

100Min

Withstanding Voltage

500V AC for 1 minute

Shall be free from Dielectric Breakage

 

3. Mechanical Performance

Item

Test Condition

Performance

Operating Force

 

As per Individual Specifications

Stop Strength

500gf for 1minute

No Terminal Rejectionand Insulator Breakage

Lever strength

2Kgf for 15 seconds

No Deformation and Mechanical Problem Found

 

4. Endurance

Item

Test Condition

Performance

Life Test

10,000 Cycle Operations
(15~20Cycles/Minute) Without Load

‧Contact Resistance : 100Max
‧Operating Force : ±10%Initial Value -30
‧insulation Resistance :10
 Min
‧Withstand Voltage : 250V AC for 1minute

Cold Test

-20±3℃ for 48±5 Hours
After Test, Kept in Normal Condition for 1Hours, to be Measured within 1Hour.

Equality to Initial Specifications

Dry Heat Proof

80±2℃ for 48±55 hours
After Test, kept in Normal Condition for 1Hour, to be Measured within 1Hour.

Equality to Initial Specifications

 

 5. Solder Heat Resistance : Auto Soldering : 260° ± 5℃/3Seconds
                                        Manual Soldering : 350° ±5℃/3Seconds

 

 6. Explanation of Changeover Timing

Shorting

Non-shorting

Switching action is accomplished after electrical connections have been made once across terminals during circuit selection.(Terminals① ,② and ③electrically connected once)

Electrical connections are turned off once across terminals during circuit selection.
(Terminals① ,② and ③ are electrically turned off once)

  ① ② ③  

① ② ③

① ② ③

① ② ③

    ① ② ③ 

① ② ③

↓   ↓   ↓ 

↓   ↓   ↓ 

↓   ↓   ↓

↓   ↓   ↓ 

↓   ↓   ↓ 

↓   ↓   ↓

 

        

 

   

 

 

 

    

 

 

 

Stationary position 

During switching 

After switching

Stationary position 

During switching 

After switching

 

       Common Specifications

1. Rating : 200mA 48V DC (Resistive Load)

2. Electrical Performance

Item

Test Condition

Performance

Contact Resistance

1A 5V DC

50MΩ Max

Insulation Resistance

500V DC for 1 minute

100MΩ Min

Withstanding Voltage

500V AC for 1 minute

Not Breaking Insulation

 

3. Mechanical Performance

Item

Test Condition

Performance

Operating Force

 

As per Individual Specifications

Terminal Strength

300gf for 1minute

No Terminal Rejection and Insulator Material Breakage

Lever strength

1Kg for Force for 15seconds

There shall not be any Troubles as Deviation and Bending

 

4. Mechanical Performance

Item

Test Condition

Performance

Life Test

300,000 Cycle Without Load
100,000 Cycle With 0.2A 48V DC
Pesistive Load

‧Contact Resistance : 1Ω Max
‧Operating Force : ±10,-30%Initial Value
‧insulation Resistance :10MΩ Min
‧Withstand Voltage : 500V AC for 1minute

Cold Test

20±2℃ for 96 Hours
After Test, Kept in Normal Condition for 1Hours, to be Measured within 1Hour.

‧Contact Resistance : 200mΩ Max
‧Operating Force : ±10,-30%Initial Value
‧insulation Resistance :10MΩMin
‧Withstand Voltage : 500V AC for 1minute

Dry Heat Proof

85±2℃ for 96 hours
After Test, kept in Normal Condition for 1Hour, to be Measured within 1Hour.

Moisture Resistance

40±2℃ 90~95 RH for 96 hours
After Test, kept in Normal Condition for 1Hour, to be Measured within 1Hour.

 

 5. Solder Heat Resistance : Auto Soldering : 260℃± 5℃/3 Seconds
                                        Manual Soldering : 350℃±5℃/3 Seconds

 

       Common Specifications

1. Construction

NO

Item

Performance

1-1

Dimension

Shape and dimensions subject to attached chart requlation

1-2

Appearance

Every part should be finished not to exist rust flaw crack and bad plating

 

2. Electrical Performance

NO

Item

Test Condition

Performance

3-1

Contact resistance

DC 5V, 1A by voltage droop method

30mΩ max.

3-2

Insulation resistance

DC 500V for 1 minute

100mΩ min

3-3

Withstand voltage

AC 500V (50Hz or 60Hz)fir 1 minute

No breakdown

 

3. Mechanical Performance

NO

Item

Test Condition

Performance

4-1

Insulation force

 

As per Individual Specifications

4-2

Extraction force

 

As per Individual Specifications

4-3

Terminal strength

500gf for 1 minute

No Terminal Rejection and Insulator Breakage

4-4

Lever strength

1kgf for 15 seconds

no mechanical and electrical problem

 

4. Endurance

NO

Item

Test Condition

Performance

5-1

Operating life

5,000 cycles (15~20 cycles/min)

Contact Resistance : 50mΩ Max

 

 

unloading

Insulation resitance : 100mΩ min.

 

 

 

Withstand voltage : AC 500V for 1 minute, no breakdown

 

 

 

Insertion or extraction force:

 

 

 

Within+10%~-30% of initial force

 

5. Soldering

NO

Item

Performance

7-1

Automatic soldering

260℃±5℃ 3sec. max

7-2

Manual soldering

350℃±5℃ 3sec. max 

 

       Common Specifications

1. Construction

NO

Item

Performance

1-1

Dimension

Shape and dimensions subject to attached chart requlation

1-2

Appearance

Every part should be finished not to exist rust flaw crack and bad plating

 

2. Rating Performance

3. Electrical Performance

NO

Item

Test Condition

Performance

3-1

Contact resistance

DC 5V, 1A by voltage droop method

30mΩ max.

3-2

Insulation resistance

DC 500V for 1 minute

100mΩ min

3-3

Withstand voltage

AC 500V (50Hz or 60Hz)fir 1 minute

No breakdown

 

4. Mechanical Performance

NO

Item

Test Condition

Performance

4-1

Insulation force

 

As per Individual Specifications

4-2

Extraction force

 

As per Individual Specifications

4-3

Terminal strength

500gf for 1 minute

No Terminal Rejection and Insulator Breakage

4-4

Lever strength

1 kgf for 15 seconds

no mechanical and electrical problem

 

5. Endurance

NO

Item

Test Condition

Performance

5-1

Operating life

5,000 cycles (15~20 cycles/min)

Contact Resistance : 50mΩ Max

 

 

unloading

Insulation resitance : 100mΩ min.

 

 

 

Withstand voltage : AC 500V for 1 minute, no breakdown

 

 

 

Insertion or extraction force:

 

 

 

Within+10%~-30% of initial force

 

6. Soldering

NO

Item

Performance

6-1

Being Kept in the condition at -20℃±3℃ for 48±5hours, then in normal condition for 1hour, to be measured within 1 hour Waterdrops shall be removed

Equality to specification of No. 5-1

6-2

Being kept in the condition at80℃±2℃ for 48±5hours, then in normal condition for 1hour, to be measured within 1 hour

Equality to specification of No. 5-1

 

7. Soldering

NO

Item

Performance

7-1

Automatic soldering

260℃±5℃ 3sec. max

7-2

Manual soldering

350℃±5℃ 3sec. max

 

       Common Specifications